Comment on “Transnasal balloon-assisted posterior ridge restoration for inferior orbital wall fractures”
Article information
To the Editor:
We commend Kim et al. [1] for addressing one of the most technically challenging aspects of orbital fracture reconstruction: restoration of the posterior orbital floor contour. Their emphasis on anatomical reduction using primary bone fragments supported by transnasal balloon assistance represents an innovative attempt to overcome the limitations associated with conventional flat alloplastic implants. In particular, the authors should be recognized for focusing not only on defect coverage but also on reconstruction of the native three-dimensional orbital anatomy.
The study demonstrated significant postoperative improvement in orbital volume ratio in both treatment groups, while curvature analysis suggested superior restoration of the posterior orbital floor contour in the balloon-assisted group. These findings provide valuable insight into the potential importance of posterior ridge reconstruction during inferior orbital wall repair. Nevertheless, several methodological considerations warrant further discussion.
First, the retrospective design and non-randomized patient allocation introduce an inherent risk of selection bias. Surgical technique selection was based on patient preference, and the study groups were unevenly distributed (25 patients in the alloplastic implant group versus 60 patients in the balloon-assisted group). Such imbalance may influence both radiologic and clinical outcomes, particularly because fracture severity, patient expectations, and surgeon preference may not have been equally represented between groups. Prospective randomized studies would therefore be necessary to establish whether the observed radiologic advantages are directly attributable to the surgical technique itself.
Second, although postoperative curvature restoration was statistically superior in the balloon-assisted group, this radiologic improvement was not accompanied by statistically significant differences in clinically meaningful parameters such as Hertel exophthalmometry. Both groups demonstrated relatively limited changes in globe projection, and no significant intergroup difference was observed. Previous investigations have similarly demonstrated that radiologic restoration alone does not necessarily correlate with superior functional or aesthetic outcomes after orbital fracture repair [2,3]. In addition to bony reconstruction, long-term globe position may also be influenced by orbital fat atrophy, soft tissue remodeling, and scar contracture [4].
Another important issue concerns the curvature analysis methodology itself. The three-point circumcircle approximation applied on sagittal computed tomography images represents an interesting quantitative approach; however, its clinical validation in orbital fracture reconstruction remains limited. Because orbital floor anatomy is inherently complex and threedimensional, simplified two-dimensional curvature measurements may not fully reflect the actual morphology of the reconstructed orbit [5]. More comprehensive three-dimensional volumetric or surface-mapping analyses may provide stronger evidence regarding the true anatomical benefit of posterior ridge restoration techniques.
The relatively short follow-up period also deserves consideration. Although the authors reported satisfactory outcomes at 6 months, mild posterior ridge subsidence was observed in several patients following balloon removal. Orbital remodeling and soft tissue adaptation may continue beyond the early postoperative period, particularly in larger defects. Longer followup studies would therefore be valuable to determine whether the reconstructed contour remains stable over time and whether delayed enophthalmos develops in selected cases.
Finally, although the authors emphasized the advantage of minimizing permanent alloplastic implantation, absorbable mesh support was still required in patients with residual defects after fragment reduction. Consequently, the described technique may be more appropriately interpreted as a hybrid reconstructive approach rather than a completely implant-free strategy.
Despite these limitations, Kim et al. [1] should be congratulated for highlighting the importance of posterior orbital contour restoration in inferior orbital wall fractures. Their work contributes meaningfully to the ongoing evolution of anatomically oriented orbital reconstruction and may encourage further investigation into techniques aimed at improving long-term functional and aesthetic outcomes.
Notes
Conflict of interest
No potential conflict of interest relevant to this article was reported.
Funding
None.
Author contributions
Conceptualization: Muhammed Said Aydin, Gökay Özler. Literature review: Gökay Özler. Writing–original draft: Muhammed Said Aydin. Writing–review & editing: Muhammed Said Aydin, Gökay Özler, Şükrü Kasap, Mustafa Nişanci. Supervision: Şükrü Kasap, Mustafa Nişanci. All authors read and approved the final manuscript.